HOME ABOUT US CONTACT US

 
  
X-RAY


Equipment Available.
Email us for availability and updated list.

1999 Philips Intergris BH5000 bi-plane cathlab, manufactured 1999, standard configuration of BH5000, CD, Dicom, still installed, available for deinstallation from a hospital in New Mexico in April.

1995 Siemens Multix CPH Rad Room with integred tube stand. LX 50 High frequency generator, four way float-top, chest bucky, floormounted table
with integrated tube stand. Low use, good condition before deinstallation, April 2004 Opti 150 x-ray tube. Professionally de-installed

2000 Siemens Coroskop Plus cathlab, manufactured 2000, Coroskop Hip Floor mounted C-arm, Polydoros IS-CF 100kw generator, Koornate M Floor mounted
table, 23-3 image intensifier, Megalix CAT tube, Hicor top digital with VA05B software, Acom M Archiving system, CD capable, lead shield, still
installed in good working condition, under Siemens service contract, available for deinstallation from a hospital in cedar Papids, Iowa, March,
2008,

1998 Siemens Bicor bi-plane cathlab, 2 of C-arms, 2 of Polydoros IS-CF generators, 2 of 9"II, 2 of megalix CAT X-ray tubes (made in 2002 and 2004), 2 of Videomed S, 6 of Simomed monitors, in perfect working condition before deinstallation in January 23rd 2008 from a hospital in Boston, MA,

1998 Siemens coroskop Top cathlab, manufactured 1998, Serial number: 1576, Coroskop Hip Floor mounted C-arm, Polydoros IS-C 100kw generator, Koornate M
Floor mounted table, 23-3 image intensifier, Megalix CAT tube, Hicor top digital, Acom M Archiving system, lead shield, still installed in good
working condition, under Siemens service contract, available for deinstallation from a hospital in Orlando, Florida March, 2008,

1997 Siemens Coroskop Top Cathlab, Serial number: 1436, Coroskop Hip Floor mounted C-arm, Polydoros IS-C 100kw generator, Koornate Floor mounted table,
23-3 image intensifier, Megalix 125/30/82cm tube, Hicor top digital, Acom M Archiving system, lead shield, still installed in good working condition,
under Siemens service contract, available for deinstallation from a hospital in Orlando, Florida March, 2008,

1997 Siemens Coroskop Top Cathlab,Serial number: 1381, Coroskop Hip Floor mounted C-arm, Polydoros IS-C generator, Koornate Floor mounted table, 23-3
image intensifier, Megalix 125/30/82cm tube, Hicor top digital, Acom M Archiving system, lead shield, still installed in good working condition,
under Siemens service contract, available for deinstallation Febuary, 2008.

2001 Siemens Angiostar Plus cath/angio combo lab, manufactured late of 2001,Angiography system for diagnostics and interventional procedures,Fast moving
floor mounted m onoplane C-arm gantry,Electrically adjustable KOORDINAT MP table with an anatomically contoured radiolucent floating tabletop;
pivotable from -90 to +90,High-resolution, programmable and self-adjusting TV system VIDEOMED S-D,SIRECON 40-4 HDR X-ray image intensifier with low
noise and excellent resolution, High-frequency multipulse 100kW X-ray generator POLYDOROS IS-AF with CAREMATIC exposure control,Long-life MEGALIX Cat125/15/40/80-121GW X-ray tube replaced 2006, POLYTRON TOP imaging system with a resolution of 1024 3 of Simomed monitors, Dryview8700 dry laser camera, Pacslink manager has been under Siemens service contract, good working condition, available for deinstallat ion from a hosptial in Cedar Rapids, IOWA in Feb 2008,

2001 Siemens Angiostar Plus Cath/angio combo lab, manufactured late of 2001, Angiography system for diagnostics and interventional procedures,Fast moving floor
mounted monoplane C-arm gantry,Electri cally adjustable KOORDINAT MP table with an anatomically contoured radiolucent floating tabletop; pivotable from
-90 to +90,High-resolution, programmable and self-adjusting TV system VIDEOMED S-D,SIRECON 40-4 HDR X-ray image intensifier with low noise and
excellent resolution, High-frequency multipulse 100kW X-ray generator POLYDOROS IS-AF with CAREMATIC exposure control, Long-life MEGALIX
Cat125/15/40/80-121GW X-ray tube with continuously rotating anode, POLYTRON TOP imaging system with a resolution of 1024 3 of Simomed monitors,
Dryview8700 dry laser camera, Pacslink manager, under Siemens service contract, good working condition before deinstalled professionally.

1997 Siemens Neurostar Top Biplance Cath/angio combo lab, manufactured 1997, System Serial number 20104, Biplane Neurology combo lab, can be used as
cathlab, angiolab and Neuro room, with both angio and cardiac capabilities. Koordinat M floor mounted ta ble, 2 of Polydoros IS-A generator, 2 of Megalix
125/40/82CM-120GW x-ray tubes replaced 2004, 2 of Sirecon 33-4 HDR image intensifier, 2 of Videomed S TV system with total 6 of Simomed HM monitors,
Polytron Top Biplane digital with Hispeed DSA, CD capability, professionally deinstalled from UPMC

1997 Siemens Coroskop Top Cathlab, Floor mounted C-arm, Polydoros IS-C generator, Koornate M Floor mounted table, 23-3 image intensifier, Megalix
125/30/82cm 120gw tube replaced 2006, Hicor top digital, Acom Archiving system, deinstalled from a hosptial in New York in August

1998 Siemens Polystar T.O.P. remote R/F and Angiographic Multipose system, Floor Mounted Universal C arm w/ vertically adjustable single sided freely
suspended table top .. 90/90, Sirecon 40-4 ii ( 40,30,22 and 17 cm Fields ), Polydoros SX80 Generator, Megalix 125/40/82 Xray Tube, Fluorospot T.O.P
Digital, 2 Monitors in room; 1 in control area, 1 suspension in room, Dicom software,deinstalled, ex warehouse

2002 GE Advantx LCV plus Cath/Angio combo lab, manufactured may 2002, Angio/cath combo lab, 12"II, stepping table, MX150V5 tube was replaced 2005, lead shield, DLX 3 digital with version C22.09, CD, good working condition, available for deinstallation in March 20,2008, from a hospital in state of Washington

2000 GE Advantx biplane Cath/angio combo lab, manufactured 2000, Bi-Plane Angio/cadiac combo lab, 40"II on AP and 32"II on LP, 2 of Mx150 tubes, DLX3
digital, Advantage workstation with full options including compas, Automated remote Bolus Chase, Automated Hispeed spins, Biplane Dynamic Cardiac
Aquisition, 512x512 at 30/15/10/7.5 fps, dicom output both Cardiac and Angio. under GE service contract, available for deinstallation from a hospital in San Franscico, Ca in December 2008

1999 GE Advantx LCV plus Cath/Angio combo lab, manufactured 1999, Angio/cath combo lab, system ID 58465WK4, 12"II, stepping table, lead shield, CD, good
working condition, available for deinstallation in March 20,2008, from a hospital in Heartland, Florida

1996 GE Advant x LCA Plus Angio/Cath Combo lab, manufactured 1996, MPPU 100kw generator, 15" trimode II , MX150 X-ray tube,Omega 4 Angio table,
DLX3 digital with both Angio and cardiac function, deinstalled in september 2007, from a hospital in florida, USA

1997 GE Advantx LC Plus cardiac Cathlab, manufactured 1997, MPPU 100kw generator, 9" trimode II , MX150 X-ray tube,Omega 4 cardiac table, DLX3
digital, Advantx E console, Trex monitoring system, deinstalled from a hospital at providence, RI , USA

2000 GE Advanx Compact 90 Rad room, manufactred 2000, overhead tube crane, wall bucky, under GE service, available January 2008, from a hospital in NY
state

1995 Philips Integris V3000 angiolab, manufactured 1995, Ceiling mounted V3000 c-arm, overhead tube crane, 15" II, Easyvision workstation, Mark V
plus injector, deinstalle d on July 16, 2007 from a hospital in South Carolina

1993 Philips Integris V3000 single plane planes Angiolab, Manufactured 1993, steppiing table, Super CP generator, 15" image intensifier replaced 2004,
X-ray tube replaced 2004, Integris digital 6.4 version, under OEM service contract, excellent condition deinstalled on July 20 from a hospital at Madison, WI, USA

2000 Picker Clinix Plus R/F room, manufactured 2000, SP-114 Digital, 80kW Generator, Digital Imaging Deck, Quad-Mode 7.5"/9"/12"/16" Image
Intensifier, Anatomical Programming, 90/50 4-Way Float Table, Table Bucky, Automatic Exposure Controls, FlouroSave, LIH-Last Image Hold, Ceiling
Mounted Tube, Real Time Window, AutoEdge, LoopStore, AutoHost, AutoPrint, Floor/Wall Mounted Auto-Loading Wall Bucky, available for deinstallation 3-2008, from a hospital in Pittsburg.

 

 

 

ETX Medical, Inc.